BPF 2/...-250
Band-Pass Filters for the 150 MHz Band
DESCRIPTION
High power base station band-pass filters for the 140 - 175 MHz range.
The use of large ø250 mm cavities means a high Q,
resulting in a very narrow passband.
The large dimensions also mean a high power rating.
Unloaded Q of a single cavity is approx. 8000.
High frequency stability on temperature and power.
19” mounting brackets are available as an option.
ORDERING DESIGNATIONS
TYPE PRODUCT NO.
BPF 2/1-250 200000954
BPF 2/2-250 200000964
BPF 2/3-250 200000971
SPECIFICATIONS
ELECTRICAL
MODEL BPF 2/1-250 BPF 2/2-250 BPF 2/3-250
FREQ. RANGE 140 - 175
MHz
140 - 175 MHz 140 - 175 MHz
MAX. INPUT
POWER
350 W @
0.5 dB IL
150 W @
2.0 dB IL
350 W @
1.0 dB IL
150 W @
4.0 dB IL
350 W @
1.5 dB IL
150 W @
6.0 dB IL
INSERTION LOSS Adjustable
0.4 - 2.0 dB
Adjustable
0.8 - 4.0 dB
Adjustable
1.2 - 6.0 dB
IMPEDANCE Nom. 50 Ω Nom. 50 Ω Nom. 50 Ω
SWR < 1.5 < 1.5 < 1.5
MECHANICAL
TEMP. RANGE
RH 0-90% non-
condensing
–30° C →
+60° C
–30° C →
+60° C
–30° C →
+60° C
FREQ.
STABILITY
Approx. 1.5
ppm/° C
Approx. 1.5
ppm/° C
Approx. 1.5
ppm/° C
CONNECTORS N-female N-female N-female
DIMENSIONS ø250 x
600 mm
L:250 x W:500 x
H:600 mm
L:250 x W:750 x
H:600 mm
WEIGHT Approx.
4.3 kg
Approx.
8.9 kg
Approx.
14 kg
TYPICAL RESPONSE CURVES
Figure 1
TYPICAL RESPONSE CURVES
Figure 2
TYPICAL RESPONSE CURVES
Figure 3
PROCOM A/S reserve the right to amend specifications
without prior notice.
24/01/13
Page view 0
1

Summary of Contents

Page 1 - BPF 2/...-250

BPF 2/...-250Band-Pass Filters for the 150 MHz BandDESCRIPTIONHigh power base station band-pass filters for the 140 - 175 MHz range.The use of large ø

Comments to this Manuals

No comments