Procom MN060HBA User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
11
Figure 16-2 - Control Knob in The
OFF Position
(MN100HBA&MN100TBA)
Figure 17 - Pilot
OPERATING YOUR HEATER
Manual Control Models
nLIGHTINGn
INSTRUCTIONS
1. STOP! Read the safety
information on the side of
heater.
2. Check that gas supply to
heater is on.
3. Push in gas control knob
slightly and turn clockwise to
the OFF position.
4. Wait five (5) minutes to clear
out any air. Then smell for
gas, including near the floor.
If you smell gas, STOP!
Follow B in the safety
information on the side of the
heater. If you do not smell
gas, go to the next step.
5. Push in gas control knob
slightly and turn
counterclockwise to
PILOT/IGN and depress for
five(5) seconds
NOTE: The first time that the
heater is operated after
connecting the gas supply , the
control knob should be depressed
for about thirty (30) seconds. This
will allow air to bleed from the gas
system.
6. With control knob pressed in,
push down and release the
ignitor button. This will light
pilot. If needed, keep pressing
ignitor button until pilot lights.
7. Keep control knob depressed
for ten (10) seconds after
lighting pilot. If pilot goes out,
repeat steps 5,6 and 7.
8. To select the desired heating
level, partially press down the
control knob slightly and rotate
counterclockwise . Release the
downward pressure on the knob
while continuing to turn until the
knob locks at the desired setting
position. Do not operate
between locked positions.
l Set control knob to desired
heating position.
NOTE: Both HIGH and LOW
are locked positions. You
must press in control knob
before turning it from these
positions.
nTO TURN OFFn
GAS TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
2. Turn off all electric power to
the appliance if service is to
be performed.
Shutting Off Burner Only
(Pilot Stays Lit)
Turn control knob clockwise
to the PILOT/IGN position.
nMANUAL LIGHTINGn
PROCEDURE
1. Remove lower front panel(see
Figure 7 page 7).
2. Follow steps 1 through 5
under Lighting Instructions.
3. With control knob pressed in,
strike match. Hold match to
pilot until pilot lights.
4. Keep control knob pressed in
for 30 seconds after lighting
pilot. After 30 seconds, release
control knob. Follow step 8
under Lighting Instructions.
5. Replace lower front panel.
CAUTION: Do not try to
adjust heating levels by using
the equipment shutoff valve.
Figure 16 -1- Control Knob In
The OFF Position (MN060HBA)
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 23 24