DCB 890-2300-7/16
DESCRIPTION
DC-block for 890 - 2300 MHz.
DC tap connected to a 3-pole DIN connector.
Don’t exceed 24 volts.
The DIN connector has internal overvoltage protection.
2 models available: DC tab on male or female connector.
ORDERING DESIGNATIONS
TYPE PRODUCT NO.
DCB 890-2300-7/16 210001184
DCB 890-2300-7/16-F(D)-M Male connector 210001188
DCB 890-2300-7/16-F-M (D) Female connector 210001189
SPECIFICATIONS
ELECTRICAL
MODEL
DCB 890-2300-7/16-F(D)-M or
DCB 890-2300-7/16-F-M (D)
FREQUENCY 890 - 2300 MHz
MAX. INPUT POWER 250 W
INSERTION LOSS < 0.1 dB
MAX. VOLTAGE AT DIN-CONNECTOR 24 V
IMPEDANCE Nom. 50 Ω
SWR ≤ 1.25
MECHANICAL
TEMP. RANGE –30° C → +60° C
CONNECTORS 7/16 DIN-female / 7/16 DIN-male
DIMENSIONS (L x W x H) 80 x 43 x 55 mm
WEIGHT Approx. 300 g
TYPICAL RESPONCE CURVE
PROCOM A/S reserve the right to amend specifications
without prior notice.
21/12/12