Page 2 of 12
SPECIFICATIONS:___________________________
• 8 isolated relay outputs, 120VAC, 6A, NO or NC
• Additional relay cards available (8 outputs each)
• 2 isolated discrete inputs, 120VAC/DC
• 1 analog output, 0-10VDC (+/-4%)
• RS232 serial port for programming
• 900MHz one way radio with 8 channels
• Operational range of 0 - 300 feet
• Output and input active indicators
• Power and data indicators
• 8 bit controller with 32K flash and CPU watchdog
• Powered by 100VAC to 240VAC, 50Hz or 60Hz
• Remote antenna mount up to 30 feet
• Operational temperature range of 0ºC to +70ºC
• Storage temperature range of -40ºC to +85ºC
• Logic customization available
• 8 inches X 4.125 inches X 4 inches, 3 LB
• Relay life rated at 1 million cycles assure reliable operation
• Rugged aluminum enclosure with panel mount flange
• Removable screw clamp connectors handle up to 12 gauge wire
APPLICATION:______________________________
The Process Communicator is a general purpose embedded controller that
can be used in a wide variety of applications. The ProComm responds to
any complete message received from operator handheld stations. This
alllows ProComm systems to support multiple operators. If operators
attempt to operate equipment at the same moment, the RF messages will be
contaminated and the ProComm will ignore both commands. The ProComm
is designed to respond when data is received from an operator handheld
station. Continuous communication is not supported and the lack of RF
input is not considered an alarm condition.
Two systems are diagrammed in this section as examples of possible
applications.
The first diagram shows the ProComm applied to a hydraulic control system.
A pump motor is controlled along with two hydraulic solenoid valves. A
TriggerPad handstation is shown as the operator’s handheld station.
Comments to this Manuals