2
TABLE OF CONTENTS
Important Safety Information....................................................................................................................3
Product Features.................................................................................................................................4
Air For Combustion and Ventilation............................................................................................................5
Installation ........................................................................................................................................6
Installing Logs.....................................................................................................................................9
Operation.........................................................................................................................................10
Care & Maintenance............................................................................................................................11
Troubleshooting.................................................................................................................................12
Replacement Parts..............................................................................................................................13
IMPORTANT: Read instructions and warnings carefully before starting installation. Failure to follow these instructions may result
in a possible re hazard and will void the warranty.
PRODUCT SPECIFICATIONS
MODEL #
BTU Input
Natural Gas
BTU Input
Propane Gas
Minimum
Vent Opening
WAN18N-2 45,000 45,000 8 in. dia.
WAN24N-2 55,000 55,000 8 in. dia.
MINIMUM FIREBOX SIZES
MODEL #
Front
Width *
Back
Width *
Depth Height
WAN18N-2 24
in. 18
in. 15
in. 18
in.
WAN24N-2 28
in. 22
in. 15
in. 18
in.
FUEL INLET PRESSURE
SPECIFICATIONS (W.C.)
Min. Max.
Natural Gas 5.5
in. 10.5
in.
Propane Gas 11
in. 13
in.
BURNER ORIFICE
MODEL # NUM. (NATURAL) NUM. (PROPANE/LP)
WAN18N-2 273 205
WAN24N-2 304 225
NUM. is printed on orice
* Add 4 in. when using on/off valve safety pilot kit
Note: This vented appliance must be installed only in a solid-fuel burning replace with a working ue and constructed of
noncombustible material.
The charts indicate technical information regarding the installation of your gas log set. Please make sure that all of the
specications shown are applicable before installation is attempted. The replace must include a working ue and venting
system with the minimum openings shown as below.