Important Safety Information....................................................................................................................3
Product Features.................................................................................................................................4
Air For Combustion and Ventilation............................................................................................................5
Installation ........................................................................................................................................6
Installing Logs.....................................................................................................................................9
Operation.........................................................................................................................................10
Care & Maintenance............................................................................................................................11
Troubleshooting.................................................................................................................................12
Replacement Parts..............................................................................................................................13
IMPORTANT: Read instructions and warnings carefully before starting installation. Failure to follow these instructions may result
in a possible re hazard and will void the warranty.
PRODUCT SPECIFICATIONS
MODEL #
BTU Input
Natural Gas
BTU Input
Propane Gas
Minimum
Vent Opening
WAN18N-2 45,000 45,000 8 in. dia.
WAN24N-2 55,000 55,000 8 in. dia.
MINIMUM FIREBOX SIZES
MODEL #
Front
Width *
Back
Width *
Depth Height
WAN18N-2 24
in. 18
in. 15
in. 18
in.
WAN24N-2 28
in. 22
in. 15
in. 18
in.
FUEL INLET PRESSURE
SPECIFICATIONS (W.C.)
Min. Max.
Natural Gas 5.5
in. 10.5
in.
Propane Gas 11
in. 13
in.
BURNER ORIFICE
MODEL # NUM. (NATURAL) NUM. (PROPANE/LP)
WAN18N-2 273 205
WAN24N-2 304 225
NUM. is printed on orice
* Add 4 in. when using on/off valve safety pilot kit
Note: This vented appliance must be installed only in a solid-fuel burning replace with a working ue and constructed of
noncombustible material.
The charts indicate technical information regarding the installation of your gas log set. Please make sure that all of the
specications shown are applicable before installation is attempted. The replace must include a working ue and venting
system with the minimum openings shown as below.