5200000-01B
MODEL MD100HBA MD200TBA-BB MD300TBA-BB
BTU (available) 10,000 20,000 30,000
Ignition Electric Piezo Electric Piezo Electric Piezo
Gas Type Using Natural Gas Using Natural Gas Using Natural Gas
Pressure Regulator Setting 4" W.C. 4" W.C. 4" W.C.
Inlet Gas Pressure*
(inches of water)
Maximum 10.5" Maximum 10.5" Maximum 10.5"
Minimum 5" Minimum 5" Minimum 5"
Gas Type Using Propane Gas Using Propane Gas Using Propane Gas
Pressure Regulator Setting 9" W.C. 9" W.C. 9" W.C.
Inlet Gas Pressure*
(inches of water)
Maximum 14" Maximum 14" Maximum 14"
Minimum 11" Minimum 11" Minimum 11"
Heater Dimensions (HxWxD)
19
1
/
8
" × 14
1
/
8
" × 6
3
/
8
" 23
1
/
2
" × 19
1
/
4
" × 8" 23
1
/
2
" x 26
5
/
8
" x 8"
Carton Dimensions (HxWxD)
22 ×16
3
/
4
" × 8
1
/
8
" 25
3
/
4
" × 21
3
/
4
" × 9
1
/
4
" 25
3
/
4
" x 28
1
/
2
" x 9
1
/
4
"
Heater Weight 14.1 lbs 25.1 lbs 31 lbs
Shipping Weight 17.1 lbs 29.1 lbs 36 lbs
SPECIFICATIONS
QUALIFIED INSTALLING AGENCY
Only a qualied agency should install and
replace gas piping, gas utilization equipment
or accessories, and repair and equipment ser-
vicing. The term “qualied agency” means any
individual, rm, corporation, or company that
either in person or through a representative
is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing,
or servicing equipment; that is experienced
in such work; that is familiar with all precau-
tions required; and that has complied with
all the requirement of the authority having
jurisdiction.
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot shuts off the heater if there is not
enough fresh air.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
Propane/LP or Natural gas. The heater is
shipped from the factory ready for connect-
ing to Propane/LP. The heater can easily be
changed to Natural gas by having your quali-
ed installer follow the instructions on page
13 and the markings on the heater.
THERMOSTATIC CONTROL
(Thermostat Models Only)
These heaters have a control valve with a
thermostat sensing bulb. This results in the
greatest heater comfort and may result in
lower gas bills.